Our series and shunt voltage references, with options for high-accuracy, low-noise and general-purpose use, can be implemented in many types of data conversion and signal conditioning applications including data acquisition systems, measurement devices and sensors, industrial controls and medical devices. We offer a family of devices with 0.1% initial accuracy, devices that support a wide selection of voltages, from 1V to 4.096V, and industry-standard solutions to meet your design’s requirements.
| Microchip Series | Vcc Range (V) | Max. Load Current (mA) | Initial Accuracy (max.%) | Temp. Coefficient (ppm/°C) | Output Current Max | Packages | Datasheet |
|---|---|---|---|---|---|---|---|
| Microchip Series | Vcc Range (V) | Max. Load Current (mA) | Initial Accuracy (max.%) | Temp. Coefficient (ppm/°C) | Output Current Max | Packages | Datasheet |
| LM4040 | 0 - 15 | 15 | 0.5 | 100 | 15mA | 3/SOT-23 | |
| LM4041 | 0 - 15 | 12 | 0.5 | 100 | 12mA | 3/SOT-23 | |
| MCP1501 | 1.65 - 5.5 | 20 | 0.1 | 50 | 20mA | 6/SOT-23 | |
| MCP1525 | 2.7 - 5.5 | 2 | 1 | 50 | 2mA | 8/SOIC | |
| MCP1541 | 4.3 - 5.5 | 2 | 1 | 50 | 2mA | 8/WDFN | |
| MIC4043 | 0 - 10 | 15 | 1 | 15mA | 3/SOT-23 |