| Daco Part Numbers | Product Status | VRRM (VPK) | Current (Per pkg) (A) | IF @Tc (Per diode) (A) | @Tc (°C) | IFSM Max (A) | VF @25°C (V) | Configuration | Trr (ns) | IR @25°C (µA) | IR @125°C (mA) | TJ (°C) | Package | Datasheet | Daco Part Numbers | Product Status | VRRM (VPK) | Current (Per pkg) (A) | IF @Tc (Per diode) (A) | @Tc (°C) | IFSM Max (A) | VF @25°C (V) | Configuration | Trr (ns) | IR @25°C (µA) | IR @125°C (mA) | TJ (°C) | Package | Datasheet |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MURTT10040 | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | Common Cathode | 75 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT10040R | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | Common Anode | 75 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT10040A | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | A Common Cathode | 75 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT10040AR | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | AR Common anode | 75 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT10060 | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT10060R | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT10060A | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT10060AR | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100100 | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100100R | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100100A | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100100AR | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100120 | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100120R | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100120A | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT100120AR | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20040 | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20040R | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20040A | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20040AR | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20060 | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20060R | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20060A | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT20060AR | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200100 | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200100R | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | Common Anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200100A | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | A Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200100AR | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | AR Common anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200120 | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200120R | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | Common Anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200120A | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | A Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200120AR | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | AR Common anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30040 | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Cathode | 100 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30040R | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Anode | 100 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30040A | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | A Common Cathode | 100 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30040AR | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | AR Common anode | 100 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30060 | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | Common Cathode | 105 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30060R | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | Common Anode | 105 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30060AV | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | A Common Cathode | 105 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT30060AR | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | AR Common anode | 105 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300100 | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300100R | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | Common Anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300100A | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | A Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300100AR | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | AR Common anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300120 | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300120R | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | Common Anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300120A | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | A Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT300120AR | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | AR Common anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT40060 | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | Common Cathode | 170 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT40060R | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | Common Anode | 170 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT40060A | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | A Common Cathode | 170 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT40060AR | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | AR Common anode | 170 | 25 | 3 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT400120 | Active | 1200 | 400 | 200 | 125 | 5000 | 2.35 | Common Cathode | 200 | 30 | 6 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT400120R | Active | 1200 | 400 | 200 | 125 | 5000 | 2.35 | Common Anode | 200 | 30 | 6 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT400120A | Active | 1200 | 400 | 200 | 125 | 5000 | 2.35 | A Common Cathode | 200 | 30 | 6 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT400120AR | Active | 1200 | 400 | 200 | 125 | 5000 | 2.35 | AR Common anode | 200 | 30 | 6 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200120AD | Active | 1200 | 400 | 200 | 125 | 5000 | 2.35 | AD Doubler | 200 | 30 | 6 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200120ADR | Active | 1200 | 400 | 200 | 125 | 5000 | 2.35 | ADR Doubler | 200 | 30 | 6 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTT200120D | Active | 1200 | 400 | 200 | 125 | 5000 | 2.35 | Doubler | 200 | 30 | 6 | -55°C to +175°C | TO-240AA (Isolated) | |
| MURTTA10040 | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | Common Cathode | 75 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA10040R | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | Common Anode | 75 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA10040A | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | A Common Cathode | 75 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA10040AR | Active | 400 | 100 | 50 | 140 | 1300 | 1.3 | AR Common anode | 75 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA10060 | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA10060R | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA10060A | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA10060AR | Active | 600 | 100 | 50 | 140 | 1300 | 1.5 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100100 | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100100R | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100100A | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100100AR | Active | 1000 | 100 | 50 | 140 | 1300 | 2.35 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100120 | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100120R | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100120A | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA100120AR | Active | 1200 | 100 | 50 | 140 | 1300 | 2.35 | AR Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20040 | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20040R | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20040A | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20040AR | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20060 | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20060R | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | Common Anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20060A | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | A Common Cathode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA20060AR | Active | 600 | 200 | 100 | 140 | 2000 | 1.5 | AR Common anode | 90 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200100 | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200100R | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | Common Anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200100A | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | A Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200100AR | Active | 1000 | 200 | 100 | 140 | 2000 | 2.35 | AR Common anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200120 | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200120R | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | Common Anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200120A | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | A Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA200120AR | Active | 1200 | 200 | 100 | 140 | 2000 | 2.35 | AR Common anode | 130 | 25 | 2 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30040 | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Cathode | 100 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30040R | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Anode | 100 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30040A | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | A Common Cathode | 100 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30040AR | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | AR Common anode | 100 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30060 | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | Common Cathode | 105 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30060R | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | Common Anode | 105 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30060A | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | A Common Cathode | 105 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA30060AR | Active | 600 | 300 | 150 | 125 | 2750 | 1.5 | AR Common anode | 105 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300100 | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300100R | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | Common Anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300100A | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | A Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300100AR | Active | 1000 | 300 | 150 | 125 | 2750 | 2.35 | AR Common anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300120 | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300120R | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | Common Anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300120A | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | A Common Cathode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA300120AR | Active | 1200 | 300 | 150 | 125 | 2750 | 2.35 | AR Common Anode | 135 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA40060 | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | Common Cathode | 170 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA40060R | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | Common Anode | 170 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA40060A | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | A Common Cathode | 170 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURTTA40060AR | Active | 600 | 400 | 200 | 125 | 3300 | 1.5 | AR Common Anode | 170 | 25 | 3 | -55°C to +175°C | TO-240AAC (Isolated) | |
| MURI2X30-02A | Active | 200 | 60 | 30 | 125 | 400 | 1 | Dual | 60 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X30-04A | Active | 400 | 60 | 30 | 125 | 400 | 1.3 | Dual | 60 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X60-02A | Active | 200 | 120 | 60 | 125 | 900 | 1 | Dual | 75 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X60-04A | Active | 400 | 120 | 60 | 125 | 900 | 1.3 | Dual | 75 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X60-06A | Active | 600 | 120 | 60 | 125 | 900 | 1.4 | Dual | 90 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X60-10A | Active | 1000 | 120 | 60 | 125 | 900 | 2.35 | Dual | 90 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X60-12A | Active | 1200 | 120 | 60 | 125 | 900 | 2.35 | Dual | 90 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X100-02A | Active | 200 | 200 | 100 | 125 | 1600 | 1 | Dual | 75 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X100-04A | Active | 400 | 200 | 100 | 125 | 1600 | 1.3 | Dual | 90 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X101-04A | Active | 400 | 200 | 100 | 125 | 1600 | 1.25 | Dual | 80 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X100-05A | Active | 500 | 200 | 100 | 125 | 1600 | 1.2 | Dual | 90 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X101-06A | Active | 600 | 200 | 100 | 125 | 1600 | 1.35 | Dual | 90 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X100-10A | Active | 1000 | 200 | 100 | 125 | 1600 | 2.35 | Dual | 125 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X100-12A | Active | 1200 | 200 | 100 | 125 | 1600 | 2.35 | Dual | 125 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X101-12A | Active | 1200 | 200 | 100 | 125 | 2500 | 2.35 | Dual | 125 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X120-02A | Active | 200 | 240 | 120 | 100 | 2100 | 1 | Dual | 100 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X120-04A | Active | 400 | 240 | 120 | 100 | 2100 | 1.3 | Dual | 100 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X121-04A | Active | 400 | 240 | 120 | 100 | 2100 | 1.125 | Dual | 100 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X120-06A | Active | 600 | 240 | 120 | 100 | 2100 | 1.4 | Dual | 105 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2X120-10A | Active | 1000 | 240 | 120 | 100 | 2100 | 2.35 | Dual | 135 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURI2x120-12A | Active | 1200 | 240 | 120 | 100 | 2100 | 2.35 | Dual | 135 | 25 | 3 | -55°C to +175°C | SOT-227 | |
| MURQ20020CT | Active | 200 | 200 | 100 | 140 | 2000 | 0.95 | Common Cathode | 75 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ20020CTR | Active | 200 | 200 | 100 | 140 | 2000 | 0.95 | Common Anode | 75 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ200A40CT | Active | 400 | 200 | 100 | 140 | 2000 | 1.1 | Common Cathode | 90 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ200A40CTR | Active | 400 | 200 | 100 | 140 | 2000 | 1.1 | Common Anode | 90 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ20040CT | Active | 400 | 200 | 100 | 140 | 2100 | 1.1 | Common Cathode | 90 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ20040CTR | Active | 400 | 200 | 100 | 140 | 2100 | 1.1 | Common Anode | 90 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ200A60CT | Active | 600 | 200 | 100 | 140 | 2100 | 1.15 | Common Cathode | 110 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ200A60CTR | Active | 600 | 200 | 100 | 140 | 2100 | 1.15 | Common Anode | 110 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ200120CT | Active | 1200 | 200 | 100 | 140 | 2100 | 1.8 | Common Cathode | 125 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ200120CTR | Active | 1200 | 200 | 100 | 140 | 2100 | 1.8 | Common Anode | 125 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ30020CT | Active | 200 | 300 | 150 | 125 | 2750 | 0.95 | Common Cathode | 100 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ30020CTR | Active | 200 | 300 | 150 | 125 | 2750 | 0.95 | Common Anode | 100 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ30040CT | Active | 400 | 300 | 150 | 125 | 2600 | 1.1 | Common Cathode | 100 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ30040CTR | Active | 400 | 300 | 150 | 125 | 2600 | 1.1 | Common Anode | 100 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ300A60CT | Active | 600 | 300 | 150 | 125 | 2600 | 1.15 | Common Cathode | 105 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ300A60CTR | Active | 600 | 300 | 150 | 125 | 2600 | 1.15 | Common Anode | 105 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ300120CT | Active | 1200 | 300 | 150 | 125 | 2600 | 1.8 | Common Cathode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ300120CTR | Active | 1200 | 300 | 150 | 125 | 2600 | 1.8 | Common Anode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ40020CT | Active | 200 | 400 | 200 | 125 | 3800 | 0.95 | Common Cathode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ40020CTR | Active | 200 | 400 | 200 | 125 | 3800 | 0.95 | Common Anode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ40040CT | Active | 400 | 400 | 200 | 125 | 3400 | 1.1 | Common Cathode | 180 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ40040CTR | Active | 400 | 400 | 200 | 125 | 3400 | 1.1 | Common Anode | 180 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ400A60CT | Active | 600 | 400 | 200 | 125 | 3400 | 1.15 | Common Cathode | 180 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MURQ400A60CTR | Active | 600 | 400 | 200 | 125 | 3400 | 1.15 | Common Anode | 180 | 25 | 3 | -55°C to +175°C | Twin Tower Q | |
| MUR10020CT | Active | 200 | 100 | 50 | 140 | 1500 | 1 | Common Cathode | 75 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR10020CTR | Active | 200 | 100 | 50 | 140 | 1500 | 1 | Common Anode | 75 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR20020CT | Active | 200 | 200 | 100 | 140 | 2000 | 1 | Common Cathode | 75 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR20020CTR | Active | 200 | 200 | 100 | 140 | 2000 | 1 | Common Anode | 75 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR20040CT | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Cathode | 90 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR20040CTR | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Anode | 90 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR200A60CT | Active | 600 | 200 | 100 | 140 | 2000 | 1.45 | Common Cathode | 110 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR200A60CTR | Active | 600 | 200 | 100 | 140 | 2000 | 1.45 | Common Anode | 110 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR200120CT | Active | 600 | 200 | 100 | 140 | 2100 | 2.35 | Common Cathode | 125 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR200120CTR | Active | 600 | 200 | 100 | 140 | 2100 | 2.35 | Common Anode | 125 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR30020CT | Active | 200 | 300 | 150 | 125 | 2750 | 1 | Common Cathode | 100 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR30020CTR | Active | 200 | 300 | 150 | 125 | 2750 | 1 | Common Anode | 100 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR30040CT | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Cathode | 110 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR30040CTR | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Anode | 110 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR30060CT | Active | 600 | 300 | 150 | 125 | 2750 | 1.7 | Common Cathode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR30060CTR | Active | 600 | 300 | 150 | 125 | 2750 | 1.7 | Common Anode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR300A60CT | Active | 600 | 300 | 150 | 125 | 2750 | 1.45 | Common Cathode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR300A60CTR | Active | 600 | 300 | 150 | 125 | 2750 | 1.45 | Common Anode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR40020CT | Active | 200 | 400 | 200 | 125 | 3300 | 1 | Common Cathode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR40020CTR | Active | 200 | 400 | 200 | 125 | 3300 | 1 | Common Anode | 150 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR400A40CT | Active | 400 | 400 | 200 | 125 | 3300 | 1.3 | Common Cathode | 170 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR400A40CTR | Active | 400 | 400 | 200 | 125 | 3300 | 1.3 | Common Anode | 170 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR400A60CT | Active | 600 | 400 | 200 | 125 | 3300 | 1.45 | Common Cathode | 200 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MUR400A60CTR | Active | 600 | 400 | 200 | 125 | 3300 | 1.45 | Common Anode | 200 | 25 | 3 | -55°C to +175°C | Twin Tower | |
| MURA40020CT | Active | 200 | 400 | 200 | 125 | 3300 | 1 | Common Cathode | 150 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA40020CTR | Active | 200 | 400 | 200 | 125 | 3300 | 1 | Common Anode | 150 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA40040CT | Active | 400 | 400 | 200 | 125 | 3300 | 1.3 | Common Cathode | 180 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA40040CTR | Active | 400 | 400 | 200 | 125 | 3300 | 1.3 | Common Anode | 180 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA400A60CT | Active | 600 | 400 | 200 | 125 | 3300 | 1.45 | Common Cathode | 240 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA400A60CTR | Active | 600 | 400 | 200 | 125 | 3300 | 1.45 | Common Anode | 240 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA60020CT | Active | 200 | 600 | 300 | 125 | 4400 | 1 | Common Cathode | 250 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA60020CTR | Active | 200 | 600 | 300 | 125 | 4400 | 1 | Common Anode | 250 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA60040CT | Active | 400 | 600 | 300 | 125 | 4400 | 1.3 | Common Cathode | 250 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA60040CTR | Active | 400 | 600 | 300 | 125 | 4400 | 1.3 | Common Anode | 250 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA600A60CT | Active | 600 | 600 | 300 | 125 | 4400 | 1.45 | Common Cathode | 280 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURA600A60CTR | Active | 600 | 600 | 300 | 125 | 4400 | 1.45 | Common Anode | 280 | 25 | 3 | -55°C to +175°C | Heavy Twin Tower | |
| MURT10040 | Active | 400 | 100 | 50 | 140 | 1500 | 1.3 | Common Cathode | 90 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT10040R | Active | 400 | 100 | 50 | 140 | 1500 | 1.3 | Common Anode | 90 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT100A60 | Active | 600 | 100 | 50 | 140 | 1500 | 1.45 | Common Cathode | 110 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT100A60R | Active | 600 | 100 | 50 | 140 | 1500 | 1.45 | Common Anode | 110 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT20020 | Active | 200 | 200 | 100 | 140 | 2000 | 1 | Common Cathode | 75 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT20020R | Active | 200 | 200 | 100 | 140 | 2000 | 1 | Common Anode | 75 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT20040 | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Cathode | 90 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT20040R | Active | 400 | 200 | 100 | 140 | 2000 | 1.3 | Common Anode | 90 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT200A60 | Active | 600 | 200 | 100 | 140 | 2000 | 1.45 | Common Cathode | 110 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT200A60R | Active | 600 | 200 | 100 | 140 | 2000 | 1.45 | Common Anode | 110 | 25 | 1 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT201120 | Active | 1200 | 200 | 100 | 140 | 2000 | 2.4 | Common Cathode | 130 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT201120R | Active | 1200 | 200 | 100 | 140 | 2000 | 2.4 | Common Anode | 130 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT30020 | Active | 200 | 300 | 150 | 125 | 2750 | 1 | Common Cathode | 100 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT30020R | Active | 200 | 300 | 150 | 125 | 2750 | 1 | Common Anode | 100 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT30040 | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Cathode | 110 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT30040R | Active | 400 | 300 | 150 | 125 | 2750 | 1.3 | Common Anode | 110 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT300A60 | Active | 600 | 300 | 150 | 125 | 2750 | 1.45 | Common Cathode | 150 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT300A60R | Active | 600 | 300 | 150 | 125 | 2750 | 1.45 | Common Anode | 150 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT300120 | Active | 1200 | 300 | 150 | 125 | 2750 | 2.4 | Common Cathode | 150 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT300120R | Active | 1200 | 300 | 150 | 125 | 2750 | 2.4 | Common Anode | 150 | 25 | 2 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT40020 | Active | 200 | 400 | 200 | 125 | 3300 | 1 | Common Cathode | 150 | 25 | 3 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT40020R | Active | 200 | 400 | 200 | 125 | 3300 | 1 | Common Anode | 150 | 25 | 3 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT40040 | Active | 400 | 400 | 200 | 125 | 3300 | 1.3 | Common Cathode | 180 | 25 | 3 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT40040R | Active | 400 | 400 | 200 | 125 | 3300 | 1.3 | Common Anode | 180 | 25 | 3 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT400A60 | Active | 600 | 400 | 200 | 125 | 3300 | 1.45 | Common Cathode | 240 | 25 | 3 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURT400A60R | Active | 600 | 400 | 200 | 125 | 3300 | 1.45 | Common Anode | 240 | 25 | 3 | -55°C to +175°C | TO-244AB (Isolated) | |
| MURKA300120 | Active | 1200 | 300 | 150 | 100 | 3500 | 2.35 | Common Cathode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA300120R | Active | 1200 | 300 | 150 | 100 | 3500 | 2.35 | Common Anode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA300120A | Active | 1200 | 300 | 150 | 100 | 3500 | 2.35 | A Common Cathode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA300120AR | Active | 1200 | 300 | 150 | 100 | 3500 | 2.35 | AR Common Anode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40040 | Active | 400 | 400 | 200 | 100 | 4000 | 1.3 | Common Cathode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40040R | Active | 400 | 400 | 200 | 100 | 4000 | 1.3 | Common Anode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40040A | Active | 400 | 400 | 200 | 100 | 4000 | 1.3 | A Common Cathode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40040AR | Active | 400 | 400 | 200 | 100 | 4000 | 1.3 | AR Common Anode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40060 | Active | 600 | 400 | 200 | 100 | 4000 | 1.4 | Common Cathode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40060R | Active | 600 | 400 | 200 | 100 | 4000 | 1.4 | Common Anode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40060A | Active | 600 | 400 | 200 | 100 | 4000 | 1.4 | A Common Cathode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40060AR | Active | 600 | 400 | 200 | 100 | 4000 | 1.4 | AR Common Anode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA400120 | Active | 1200 | 400 | 200 | 100 | 4000 | 2.35 | Common Cathode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA400120R | Active | 1200 | 400 | 200 | 100 | 4000 | 2.35 | Common Anode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA400120A | Active | 1200 | 400 | 200 | 100 | 4000 | 2.35 | A Common Cathode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA400120AR | Active | 1200 | 400 | 200 | 100 | 4000 | 2.35 | AR Common Anode | 180 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60040 | Active | 400 | 600 | 300 | 100 | 6000 | 1.3 | Common Cathode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60040R | Active | 400 | 600 | 300 | 100 | 6000 | 1.3 | Common Anode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60040A | Active | 400 | 600 | 300 | 100 | 6000 | 1.3 | A Common Cathode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60040AR | Active | 400 | 600 | 300 | 100 | 6000 | 1.3 | AR Common Anode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60060 | Active | 600 | 600 | 300 | 100 | 6000 | 1.4 | Common Cathode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60060R | Active | 600 | 600 | 300 | 100 | 6000 | 1.4 | Common Anode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60060A | Active | 600 | 600 | 300 | 100 | 6000 | 1.4 | A Common Cathode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA60060AR | Active | 600 | 600 | 300 | 100 | 6000 | 1.4 | AR Common Anode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA600120 | Active | 1200 | 600 | 300 | 100 | 6000 | 2.35 | Common Cathode | 250 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA600120R | Active | 1200 | 600 | 300 | 100 | 6000 | 2.35 | Common Anode | 250 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA600120A | Active | 1200 | 600 | 300 | 100 | 6000 | 2.35 | A Common Cathode | 250 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA600120AR | Active | 1200 | 600 | 300 | 100 | 6000 | 2.35 | AR Common Anode | 250 | 25 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80040 | Active | 400 | 800 | 400 | 100 | 8000 | 1.3 | Common Cathode | 220 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80040R | Active | 400 | 800 | 400 | 100 | 8000 | 1.3 | Common Anode | 220 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80040A | Active | 400 | 800 | 400 | 100 | 8000 | 1.3 | A Common Cathode | 220 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80040AR | Active | 400 | 800 | 400 | 100 | 8000 | 1.3 | AR Common Anode | 220 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80060 | Active | 600 | 800 | 400 | 100 | 8000 | 1.4 | Common Cathode | 230 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80060R | Active | 600 | 800 | 400 | 100 | 8000 | 1.4 | Common Anode | 230 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80060A | Active | 600 | 800 | 400 | 100 | 8000 | 1.4 | A Common Cathode | 230 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA80060AR | Active | 600 | 800 | 400 | 100 | 8000 | 1.4 | AR Common Anode | 230 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA800120 | Active | 1200 | 800 | 400 | 100 | 8000 | 2.35 | Common Cathode | 260 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA800120R | Active | 1200 | 800 | 400 | 100 | 8000 | 2.35 | Common Anode | 260 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA800120A | Active | 1200 | 800 | 400 | 100 | 8000 | 2.35 | A Common Cathode | 260 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA800120AR | Active | 1200 | 800 | 400 | 100 | 8000 | 2.35 | AR Common Anode | 260 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA20060AD | Active | 600 | 400 | 200 | 100 | 4000 | 1.4 | AD Doubler | 180 | 30 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA20060ADR | Active | 600 | 400 | 200 | 100 | 4000 | 1.4 | ADR Doubler | 180 | 30 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA20060D | Active | 600 | 400 | 200 | 100 | 4000 | 1.4 | Doubler | 180 | 30 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA30060AD | Active | 600 | 600 | 300 | 100 | 6000 | 1.35 | AD Doubler | 200 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA30060ADR | Active | 600 | 600 | 300 | 100 | 6000 | 1.35 | ADR Doubler | 200 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA30060D | Active | 600 | 600 | 300 | 100 | 6000 | 1.35 | Doubler | 200 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA300120AD | Active | 1200 | 600 | 300 | 100 | 6000 | 2.35 | AD Doubler | 250 | 50 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA300120ADR | Active | 1200 | 600 | 300 | 100 | 6000 | 2.35 | ADR Doubler | 250 | 50 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA300120D | Active | 1200 | 600 | 300 | 100 | 6000 | 2.35 | Doubler | 250 | 50 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40060AD | Active | 600 | 800 | 400 | 100 | 8000 | 1.4 | AD Doubler | 230 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40060ADR | Active | 600 | 800 | 400 | 100 | 8000 | 1.4 | ADR Doubler | 230 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA40060D | Active | 600 | 800 | 400 | 100 | 8000 | 1.4 | Doubler | 230 | 50 | 5 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA400120AD | Active | 1200 | 800 | 400 | 100 | 8000 | 2.35 | AD Doubler | 260 | 50 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA400120ADR | Active | 1200 | 800 | 400 | 100 | 8000 | 2.35 | ADR Doubler | 260 | 50 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURKA400120D | Active | 1200 | 800 | 400 | 100 | 8000 | 2.35 | Doubler | 260 | 50 | 6 | -55°C to +175°C | Heavy Three Tower KA (Isolated) | |
| MURIDK200120 | Active | 1200 | 200 | 200 | 100 | 3300 | 2.35 | Single | 200 | 50 | 5 | -55°C to +175°C | IDK (Isolated) | |
| MURIDK300120 | Active | 1200 | 300 | 300 | 100 | 4400 | 2.35 | Single | 250 | 60 | 6 | -55°C to +175°C | IDK (Isolated) | |
| MURIDK450120 | Active | 1200 | 450 | 450 | 100 | 9000 | 2.15 | Single | 350 | 50 | 10 | -55°C to +175°C | IDK (Isolated) | |
| MURTA20020 | Active | 200 | 200 | 100 | 100 | 2000 | 1 | Common Cathode | 100 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA20020R | Active | 200 | 200 | 100 | 100 | 2000 | 1 | Common Anode | 100 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA20040 | Active | 400 | 200 | 100 | 100 | 2000 | 1.3 | Common Cathode | 100 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA20040R | Active | 400 | 200 | 100 | 100 | 2000 | 1.3 | Common Anode | 100 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA200A60 | Active | 600 | 200 | 100 | 100 | 2000 | 1.45 | Common Cathode | 110 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA200A60R | Active | 600 | 200 | 100 | 100 | 2000 | 1.45 | Common Anode | 110 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA200120 | Active | 1200 | 200 | 100 | 100 | 2000 | 2.6 | Common Cathode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA200120R | Active | 1200 | 200 | 100 | 100 | 2000 | 2.6 | Common Anode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA30020 | Active | 200 | 300 | 150 | 100 | 2750 | 1 | Common Cathode | 130 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA30020R | Active | 200 | 300 | 150 | 100 | 2750 | 1 | Common Anode | 130 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA30040 | Active | 400 | 300 | 150 | 100 | 2750 | 1.3 | Common Cathode | 130 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA30040R | Active | 400 | 300 | 150 | 100 | 2750 | 1.3 | Common Anode | 130 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA300A60 | Active | 600 | 300 | 150 | 100 | 2750 | 1.45 | Common Cathode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA300A60R | Active | 600 | 300 | 150 | 100 | 2750 | 1.45 | Common Anode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA300120 | Active | 1200 | 300 | 150 | 100 | 2750 | 2.6 | Common Cathode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA300120R | Active | 1200 | 300 | 150 | 100 | 2750 | 2.6 | Common Anode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA40020 | Active | 200 | 400 | 200 | 100 | 3300 | 1 | Common Cathode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA40020R | Active | 200 | 400 | 200 | 100 | 3300 | 1 | Common Anode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA40040 | Active | 400 | 400 | 200 | 100 | 3300 | 1.3 | Common Cathode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA40040R | Active | 400 | 400 | 200 | 100 | 3300 | 1.3 | Common Anode | 150 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA400A60 | Active | 600 | 400 | 200 | 100 | 3300 | 1.45 | Common Cathode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA400A60R | Active | 600 | 400 | 200 | 100 | 3300 | 1.45 | Common Anode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA400120 | Active | 1200 | 400 | 200 | 100 | 3300 | 2.6 | Common Cathode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA400120R | Active | 1200 | 400 | 200 | 100 | 3300 | 2.6 | Common Anode | 180 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA50020 | Active | 200 | 500 | 250 | 100 | 3800 | 1 | Common Cathode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA50020R | Active | 200 | 500 | 250 | 100 | 3800 | 1 | Common Anode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA50040 | Active | 400 | 500 | 250 | 100 | 3800 | 1.3 | Common Cathode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA50040R | Active | 400 | 500 | 250 | 100 | 3800 | 1.3 | Common Anode | 200 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA500A60 | Active | 600 | 500 | 250 | 100 | 3800 | 1.45 | Common Cathode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA500A60R | Active | 600 | 500 | 250 | 100 | 3800 | 1.45 | Common Anode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA500120 | Active | 1200 | 500 | 250 | 100 | 3800 | 2.6 | Common Cathode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA500120R | Active | 1200 | 500 | 250 | 100 | 3800 | 2.6 | Common Anode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA60020 | Active | 200 | 600 | 300 | 100 | 4400 | 1 | Common Cathode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA60020R | Active | 200 | 600 | 300 | 100 | 4400 | 1 | Common Anode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA60040 | Active | 400 | 600 | 300 | 100 | 4400 | 1.3 | Common Cathode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA60040R | Active | 400 | 600 | 300 | 100 | 4400 | 1.3 | Common Anode | 250 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA600A60 | Active | 600 | 600 | 300 | 100 | 4400 | 1.7 | Common Cathode | 280 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA600A60R | Active | 600 | 600 | 300 | 100 | 4400 | 1.7 | Common Anode | 280 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA600120 | Active | 1200 | 600 | 300 | 100 | 4400 | 2.6 | Common Cathode | 280 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURTA600120R | Active | 1200 | 600 | 300 | 100 | 4400 | 2.6 | Common Anode | 280 | 25 | 5 | -55°C to +175°C | Heavy Three Tower (Isolated) | |
| MURIDA20020 | Active | 200 | 200 | 200 | 100 | 3300 | 1 | Single | 150 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURIDA20040 | Active | 400 | 200 | 200 | 100 | 3300 | 1.3 | Single | 180 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURIDA200A60 | Active | 600 | 200 | 200 | 100 | 3300 | 1.45 | Single | 200 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURIDA200120 | Active | 1200 | 200 | 200 | 100 | 3300 | 2.6 | Single | 200 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURIDA30020 | Active | 200 | 300 | 300 | 100 | 4400 | 0.95 | Single | 235 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURIDA30040 | Active | 400 | 300 | 300 | 100 | 4400 | 1.3 | Single | 200 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURIDA300A60 | Active | 600 | 300 | 300 | 100 | 4400 | 1.35 | Single | 200 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURIDA300120 | Active | 1200 | 300 | 300 | 100 | 4400 | 2.35 | Single | 230 | 25 | 5 | -55°C to +175°C | Heavy Diode (Isolated) | |
| MURH7020 | Active | 200 | 70 | 70 | 125 | 1500 | 1 | Single | 75 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH7020R | Active | 200 | 70 | 70 | 125 | 1500 | 1 | Single Reverse Polarity | 75 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH7040 | Active | 400 | 70 | 70 | 125 | 1500 | 1.3 | Single | 90 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH7040R | Active | 400 | 70 | 70 | 125 | 1500 | 1.3 | Single Reverse Polarity | 90 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH7060 | Active | 600 | 70 | 70 | 125 | 1500 | 1.7 | Single | 110 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH7060R | Active | 600 | 70 | 70 | 125 | 1500 | 1.7 | Single Reverse Polarity | 110 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH10020 | Active | 200 | 100 | 100 | 140 | 2000 | 1 | Single | 75 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH10020R | Active | 200 | 100 | 100 | 140 | 2000 | 1 | Single Reverse Polarity | 75 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH10040 | Active | 400 | 100 | 100 | 140 | 2000 | 1.3 | Single | 90 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH10040R | Active | 400 | 100 | 100 | 140 | 2000 | 1.3 | Single Reverse Polarity | 90 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH10060 | Active | 600 | 100 | 100 | 140 | 2000 | 1.7 | Single | 110 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| MURH10060R | Active | 600 | 100 | 100 | 140 | 2000 | 1.7 | Single Reverse Polarity | 110 | 25 | 3 | -55°C to +175°C | Half Pack (D-67) | |
| UFT10010 | Active | 100 | 100 | 50 | 125 | 1000 | 1 | Dual | 60 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT10020 | Active | 200 | 100 | 50 | 125 | 1000 | 1 | Dual | 60 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT10040 | Active | 400 | 100 | 50 | 125 | 1000 | 1.3 | Dual | 70 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT100A60 | Active | 600 | 100 | 50 | 125 | 1000 | 1.45 | Dual | 90 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT14010 | Active | 100 | 140 | 70 | 125 | 1300 | 1 | Dual | 75 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT14020 | Active | 200 | 140 | 70 | 125 | 1300 | 1 | Dual | 75 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT14040 | Active | 400 | 140 | 70 | 125 | 1300 | 1.3 | Dual | 85 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT14140 | Active | 400 | 140 | 70 | 125 | 1300 | 1.25 | Dual | 75 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT140A60 | Active | 600 | 140 | 70 | 125 | 1300 | 1.45 | Dual | 90 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT140100 | Active | 1000 | 140 | 70 | 125 | 1300 | 2.5 | Dual | 90 | 25 | 3 | -55°C to +175°C | Power Mod (TO-249AA) | |
| UFT7340M | Active | 400 | 70 | 35 | 125 | 800 | 1.3 | Dual | 75 | 20 | 3 | -55°C to +175°C | Mini Mod (D61-3M) | |
| UFT7360M | Active | 600 | 70 | 35 | 125 | 800 | 1.7 | Dual | 90 | 20 | 3 | -55°C to +175°C | Mini Mod (D61-3M) | |
| MUR5010a | Active | 100 | 50 | 50 | 125 | 800 | 1 | Single | 60 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR5010R | Active | 100 | 50 | 50 | 125 | 800 | 1 | Single Reverse Polarity | 60 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR5020 | Active | 200 | 50 | 50 | 125 | 800 | 1 | Single | 60 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR5020R | Active | 200 | 50 | 50 | 125 | 800 | 1 | Single Reverse Polarity | 60 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR5040 | Active | 400 | 50 | 50 | 125 | 800 | 1.25 | Single | 75 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR5040R | Active | 400 | 50 | 50 | 125 | 800 | 1.25 | Single Reverse Polarity | 75 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR5060 | Active | 600 | 50 | 50 | 125 | 800 | 1.45 | Single | 90 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR5060R | Active | 600 | 50 | 50 | 125 | 800 | 1.45 | Single Reverse Polarity | 90 | 10 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR7020 | Active | 200 | 70 | 70 | 125 | 1000 | 1 | Single | 75 | 25 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR7020R | Active | 200 | 70 | 70 | 125 | 1000 | 1 | Single Reverse Polarity | 75 | 25 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR7040 | Active | 400 | 70 | 70 | 125 | 1000 | 1.3 | Single | 75 | 25 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR7040R | Active | 400 | 70 | 70 | 125 | 1000 | 1.3 | Single Reverse Polarity | 75 | 25 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR7061 | Active | 600 | 70 | 70 | 125 | 1000 | 1.45 | Single | 90 | 25 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MUR7061R | Active | 600 | 70 | 70 | 125 | 1000 | 1.45 | Single Reverse Polarity | 90 | 25 | 3 | -55°C to +175°C | DO-5 Stud (DO-203AB) | |
| MURI2X60-17A | New | 1700 | 2 x 60 | 60 | 125 | 2000 | 2.8 | Dual | 200 | 20 | 3 | -55°C to +175°C | SOT-227 |
Choose how this site can use cookies. You can change these settings at any time.
Required for the site to work — security, network management, and remembering your privacy choices. These can't be switched off.
Remember your preferences, like language and region, for a more personal experience.
Help us understand which pages are popular and how visitors move around the site.
Let us identify business visitors and show relevant ads, and measure how campaigns perform across sites.